TemperatureSchedule (Module)
Control the temperature of a configuration
Overview
The TemperatureSchedule
module gives the ability to control the temperature of a configuration, adjusting its towards some target temperature at a predefined maximum rate per iteration of the module.
Targets
Keyword | Arguments | Default | Description |
---|---|---|---|
Configuration |
Configuration |
– | Required Target configuration on which to operate. |
Schedule
Keyword | Arguments | Default | Description |
---|---|---|---|
Rate |
double |
1.0 |
Maximal absolute change to add or subtract from the configuration’s current temperature each time the module runs in order to move it towards the target temperature. If the difference between the target and current temperatures is less than the defined rate, the configuration temperature is set to the target temperature. |
TargetTemperature |
double |
300.0 |
Target temperature for the configuration. |